Uniformat G3010
Watermain, PVC
Also called PVC watermain, C900 pipe, polyvinyl chloride watermain
Service life
Years in service. The band runs from the shortest to the longest life the sources state, so it shows how much they disagree, not how long 80% of units last. The line is the median of the stated lives.
Basis
- 75 years · Kenora: AF-6-1 Tangible Capital Asset Policy (By-law 34-2026), p17 · “Water Mains - PVC” (accounting life)Capital asset policy (amortization period). Approved on text check: the label and value were found on the cited page.
- 80 years · Kingston: Tangible Capital Assets Policy, p15 · “Water Utility - Water Pipes: PVC” (accounting life)Capital asset policy (amortization period). Approved on text check: the label and value were found on the cited page.
- 80 years · Quinte West: A09-POLICY-0034 Tangible Capital Asset Policy, p37 · “Water Mains - PVC” (accounting life)Capital asset policy (amortization period). Approved on text check: the label and value were found on the cited page.
How sources are chosen and recorded: sourcing policy.
Municipal accounting lives for water supply (G3010)
19 municipal policies from Ontario set a life for water supply as a whole, from 19 distinct tables: 15–100 years, median 60. These are amortization periods chosen for accounting, not measured lives, and they describe the system rather than this component.
Years. Each dot is one stated life and each bar a stated range; equal values stack. The dashed line is the median. Policies that copy the same table count once.
All 65 stated lives
| Municipality | As written | Years | Source |
|---|---|---|---|
| Sarnia | Water Pumping Stations - mechanical/equipment | 15 | p1 |
| The Blue Mountains | Linear - Fire Hydrants | 20 | p12 · 2019 |
| Meaford | Linear - Valves - Power Actuated | 20–30 | p19 · 2020 |
| Meaford | Linear - Valves - Gate | 25 | p19 · 2020 |
| Meaford | Linear - Valves - Air Release | 25 | p19 · 2020 |
| Orillia | Roads: Hydrants | 25 | p22 |
| Sarnia | Water Pumping Stations - pumps | 25 | p1 |
| Rainy River | Water valves/services | 30 | p11 · 2010 |
| Chapple | Fire Hydrants | 40 | p1 |
| Prince Edward | Water - Valves (Pooled) | 40 | p34 · 2022 |
| Sarnia | Fire Hydrants | 40 | p2 |
| Centre Hastings | Water infrastructure | 40–60 | p5 |
| Amherstburg | Infrastructure - Water - Water Tower | 50 | p7 · 2026 |
| Grey Highlands | Hydrants | 50 | p10 · 2026 |
| Grey Highlands | Water & Wastewater Treatment Assets - Water Tower | 50 | p11 · 2026 |
| Grey Highlands | Water & Wastewater Treatment Assets - Valve Chamber | 50 | p11 · 2026 |
| Grey Highlands | Water & Wastewater Treatment Assets - Clearwell | 50 | p11 · 2026 |
| Kapuskasing | Water Distribution System (pipes, hydrants, valves etc.) | 50 | p15 · 2009 |
| Kenora | Water Mains - Cast Iron | 50 | p17 · 2026 |
| Kingston | Water Utility - Water Pipes: DI | 50 | p15 · 2016 |
| Kingston | Water Utility - Water Pipes: Asbestos Cement | 50 | p15 · 2016 |
| Kingston | Water Utility - Water Other: Water valves | 50 | p15 · 2016 |
| Kirkland Lake | Water Distribution System (pipes, hydrants, valves etc.) | 50 | p10 · 2020 |
| Meaford | Valve Chamber | 50 | p18 · 2020 |
| Meaford | Linear - Valves - Pressure Release | 50 | p19 · 2020 |
| Meaford | Linear - Valves - Globe | 50 | p19 · 2020 |
| Quinte West · same table | Water Mains - Cast Iron | 50 | p37, p37 · 2024 |
| The Blue Mountains | Valve Chamber | 50 | p11 · 2019 |
| Trent Lakes | Water - Valves | 50 | p10 · 2009 |
| Welland | Water Systems (by component) - Water Services (includes fittings) | 50 | p9 · 2021 |
| Meaford | Linear - Fire Hydrant | 50–60 | p19 · 2020 |
| Orillia | Land Improvement (Infrastructure) - Reservoirs | 50–60 | p22 |
| Meaford | Linear - Valves - Valve Chamber | 50–80 | p19 · 2020 |
| Meaford | Linear - Valves - Maintenance Hatch | 50–80 | p19 · 2020 |
| Kenora | Water Mains - Ductile Iron | 60 | p17 · 2026 |
| Kingston | Water Utility - Water Pipes: Concrete | 60 | p15 · 2016 |
| Kingston | Water Utility - Water Other: Water hydrants | 60 | p15 · 2016 |
| Prince Edward | Water - Laterals/Connections (Pooled) | 60 | p34 · 2022 |
| Quinte West | Hydrants | 60 | p37 · 2024 |
| Rainy River | Water lines/Hydrants | 60 | p11 · 2010 |
| Sarnia | Water Distribution | 60 | p2 |
| Severn | Infrastructure - Water & Sewer - Hydrants | 60 | p402 · 2019 |
| Trent Lakes | Water - Mains | 60 | p10 · 2009 |
| Welland | Water Systems (by component) - Hydrant Assemblies | 60 | p9 · 2021 |
| Prince Edward | Water - Water Mains | 60–80 | p34 · 2022 |
| Kingston | Water Utility - Water Pipes: Average | 64 | p15 · 2016 |
| Kingston | Water Utility - Water Pipes: HDPE | 70 | p15 · 2016 |
| Prince Edward | Water - Hydrants (Pooled) | 70 | p34 · 2022 |
| Prince Edward | Water - Hydrants - Leads (Pooled) | 70 | p34 · 2022 |
| Amherstburg | Other - Pooled Assets - Fire Hydrants | 75 | p8 · 2026 |
| Grey Highlands | Watermain Pipe | 75 | p10 · 2026 |
| Kenora | Water Mains - PVC | 75 | p17 · 2026 |
| Kenora | Water Mains - PE | 75 | p17 · 2026 |
| Kenora | Water Mains - Valves | 75 | p17 · 2026 |
| Kenora | Water Mains - Hydrants | 75 | p17 · 2026 |
| Kenora | Booster Stations | 75 | p17 · 2026 |
| Kingston | Water Utility - Water Facilities: Tankage | 75 | p15 · 2016 |
| Kingston | Water Utility - Water Pipes: CI | 75 | p15 · 2016 |
| Brockton | Waterworks - Watermains | 80 | p2 · 2009 |
| Kingston | Water Utility - Water Pipes: PVC | 80 | p15 · 2016 |
| Quinte West · same table | Water Mains - Polyethylene | 80 | p37, p37, p37, p37, p37 · 2024 |
| Severn | Infrastructure - Water & Sewer - Valves | 80 | p402 · 2019 |
| Welland | Water Systems (by component) - Water Mains (includes valves & fittings) | 80 | p9 · 2021 |
| Welland | Water Systems (by component) - Chambers & Vaults (for valves & meters) | 80 | p9 · 2021 |
| Amherstburg | Infrastructure - Water - Watermains | 100 | p7 · 2026 |
Each row was matched to its page automatically: the label and the number appear in the text of the cited page. An editor has not yet compared every row with the table, so follow the page link before relying on one. About the policies · All approved rows as JSON
Preventive maintenance
No maintenance tasks are sourced for this component yet.
Open questions
- These are Ontario accounting lives from municipal capital asset policies, not planning or observed replacement data.
- No preventive maintenance tasks are sourced yet.
Know the answer? Send it with a source to [email protected].
Cite this
Citation
unfinished.one (2026). Watermain, PVC, v0.1.0. https://unfinished.one/c/watermain-pvc/v/0.1.0BibTeX
@misc{unfinished_watermain_pvc_0_1_0,
title = {Watermain, PVC},
author = {{unfinished.one}},
year = {2026},
version = {0.1.0},
url = {https://unfinished.one/c/watermain-pvc/v/0.1.0},
note = {CC BY 4.0}
}Licence CC BY 4.0 · How to cite · JSON · Versions: 0.1.0