Ontario · Single-tier municipality · population 47,845 (2021)
Cornwall
Documents
2025 Asset Management Plan City of Cornwall · 2025
Asset management plan
Stated lives
67 rows, each as written in the document and linked to its page. Policies give accounting lives (amortization periods); plans give planning lives. Neither is a measured replacement age.
2025 Asset Management Plan City of Cornwall
| As written | Years | System | Checked against | Page |
|---|---|---|---|---|
| Bridges | 73.7 | Roadways | page image | p252 |
| Large Culverts (over 3m span) | 66.2 | Storm sewer | page image | p252 |
| Pole Footings | 66 | Roadways | page image | p252 |
| Retaining Walls | 65.1 | Roadways | page image | p252 |
| Roads | 100 | Roadways | page image | p252 |
| Small Culverts (under 3m span) | 47.9 | Storm sewer | page image | p252 |
| Small Retaining Walls (under 600mm height) | 25 | Roadways | page image | p252 |
| Public Parking | 100 | Parking lots | page image | p252 |
| Parking Meters and Equipment | 12.2 | Parking lots | page image | p252 |
| Pedestrian Crossings | 26.1 | Roadways | page image | p252 |
| Street Lighting | 60 | Site lighting | page image | p252 |
| Street Signs | 17.6 | Roadways | page image | p252 |
| Traffic Signals | 27.6 | Traffic signals and other site electrical | page image | p252 |
| Roads - Arterial | 100 | Roadways | page image | p253 |
| Roads - Collector | 100 | Roadways | page image | p253 |
| Roads - Local | 100 | Roadways | page image | p253 |
| Combined Sewers | 99.6 | Sanitary sewer | page image | p299 |
| CSO Chamber | 58.9 | Sanitary sewer | page image | p299 |
| Combined Sewer - Asbestos Cement | 70 | Sanitary sewer | page image | p300 |
| Combined Sewer - Brick | 120 | Sanitary sewer | page image | p300 |
| Combined Sewer - Concrete Pipe | 100 | Sanitary sewer | page image | p300 |
| Combined Sewer - Polyvinyl Chloride | 110 | Sanitary sewer | page image | p300 |
| Combined Sewer - Reinforced Concrete | 100 | Sanitary sewer | page image | p300 |
| Combined Sewer - Stone | 100 | Sanitary sewer | page image | p300 |
| Combined Sewer - Vitrified Clay | 100 | Sanitary sewer | page image | p300 |
| Forcemains | 108.3 | Sanitary sewer | page image | p316 |
| Sanitary Sewers | 94.7 | Sanitary sewer | page image | p316 |
| Sanitary Pumping Stations | 100 | Sanitary sewer | page image | p316 |
| Sanitary Sewer - Asbestos Cement | 70 | Sanitary sewer | page image | p317 |
| Sanitary Sewer - Concrete Pipe | 100 | Sanitary sewer | page image | p317 |
| Sanitary Sewer - Concrete Pressure Pipe | 100 | Sanitary sewer | page image | p317 |
| Sanitary Sewer - Ductile Iron | 110 | Sanitary sewer | page image | p317 |
| Sanitary Sewer - High-Density Polyethylene | 110 | Sanitary sewer | page image | p317 |
| Sanitary Sewer - Polyvinyl Chloride | 110 | Sanitary sewer | page image | p317 |
| Sanitary Sewer - Reinforced Concrete | 100 | Sanitary sewer | page image | p317 |
| Sanitary Sewer - Vitrified Clay | 100 | Sanitary sewer | page image | p317 |
| Storm Sewers | 101.5 | Storm sewer | page image | p335 |
| Oil Grit Separators | 100 | Storm sewer | page image | p335 |
| Storm Sewer - Asbestos Cement | 70 | Storm sewer | page image | p336 |
| Storm Sewer - Concrete Pipe | 100 | Storm sewer | page image | p336 |
| Storm Sewer - Concrete Pressure Pipe | 100 | Storm sewer | page image | p336 |
| Storm Sewer - Corrugated Steel Pipe | 75 | Storm sewer | page image | p336 |
| Storm Sewer - High-Density Polyethylene | 110 | Storm sewer | page image | p336 |
| Storm Sewer - Polyvinyl Chloride | 110 | Storm sewer | page image | p336 |
| Storm Sewer - Reinforced Concrete | 100 | Storm sewer | page image | p336 |
| Storm Sewer - Stainless Steel | 110 | Storm sewer | page image | p336 |
| Storm Sewer - Steel | 75 | Storm sewer | page image | p336 |
| Storm Sewer - Vitrified Clay | 100 | Storm sewer | page image | p336 |
| Watermains | 95.6 | Water supply | page image | p354 |
| Reservoirs and Storage Tanks | 67 | Water supply | page image | p354 |
| Watermain - Cast Iron | 81.5 | Water supply | page image | p354 |
| Watermain - Concrete Pressure Pipe | 100 | Water supply | page image | p354 |
| Watermain - Copper | 100 | Water supply | page image | p354 |
| Watermain - Ductile Iron | 90 | Water supply | page image | p354 |
| Watermain - Polyvinyl Chloride | 110 | Water supply | page image | p354 |
| Watermain - Steel | 55 | Water supply | page image | p354 |
| Wastewater Treatment - Process Electrical | 30 | Sanitary sewer | page image | p372 |
| Wastewater Treatment - Process Instrumentation | 10 | Sanitary sewer | page image | p372 |
| Wastewater Treatment - Process Mechanical | 20 | Sanitary sewer | page image | p372 |
| Wastewater Treatment - Process Piping | 30 | Sanitary sewer | page image | p372 |
| Wastewater Treatment Plant | 63.5 | Sanitary sewer | page image | p372 |
| Water Treatment - Process Electrical | 30 | Water supply | page image | p386 |
| Water Treatment - Process Instrumentation | 10 | Water supply | page image | p386 |
| Water Treatment - Process Mechanical | 20 | Water supply | page image | p386 |
| Water Treatment - Process Piping | 30 | Water supply | page image | p386 |
| Raw Water Intake Facilities | 78 | Water supply | page image | p386 |
| Water Purification Plant | 62.6 | Water supply | page image | p386 |