By-law 2020-83, Tangible Capital Asset Policy, Appendix A Estimated Useful Lives
| As written | Years | System | Checked against | Page |
|---|---|---|---|---|
| Foundations - Standard | 100 | Foundations | page text | p16 |
| Foundations - Slab On-grade | 75–100 | Foundations | page text | p16 |
| Plumbing - System | 50 | Plumbing | page text | p16 |
| Plumbing - Fixtures | 20 | Plumbing | page text | p16 |
| Plumbing - Cistern | 50 | Plumbing | page text | p16 |
| Superstructure - Wood Framing & Trusses | 100 | Superstructure | page text | p17 |
| Superstructure - Concrete Block | 100 | Superstructure | page text | p17 |
| Plumbing - Boiler | 20 | Plumbing | page text | p17 |
| Plumbing - Septic System | 25 | Plumbing | page text | p17 |
| Plumbing - Water Treatment System | 15 | Plumbing | page text | p17 |
| Exterior Closure - Concrete Block | 50 | Exterior enclosure | page text | p17 |
| Exterior Closure - Metal Cladding | 50 | Exterior enclosure | page text | p17 |
| Exterior Closure - Wood Cladding | 40 | Exterior enclosure | page text | p17 |
| Exterior Closure - Vinyl Siding | 30 | Exterior enclosure | page text | p17 |
| Exterior Closure - Standard Doors | 30 | Exterior enclosure | page text | p17 |
| Exterior Closure - Overhead Doors | 20 | Exterior enclosure | page text | p17 |
| Exterior Closure - Windows | 25 | Exterior enclosure | page text | p17 |
| HVAC - System | 50 | HVAC | page text | p17 |
| HVAC - Furnace | 15–25 | HVAC | page text | p17 |
| HVAC - Air Distribution | 20 | HVAC | page text | p17 |
| Fire Protection - Sprinkler System | 25 | Fire protection | page text | p17 |
| Fire Protection - Alarm Panel | 25 | Fire protection | page text | p17 |
| Roof - Metal | 40–50 | Roofing | page text | p17 |
| Roof - Flat | 30 | Roofing | page text | p17 |
| Roof - Asphalt Shingles | 25 | Roofing | page text | p17 |
| Roof - Tile | 30 | Roofing | page text | p17 |
| Roof - Soffit & Fascia | 25–50 | Roofing | page text | p17 |
| Electrical - System | 50 | Electrical | page text | p17 |
| Electrical - Interior Lighting - Standard | 20 | Electrical | page text | p17 |
| Electrical - Interior Lighting - High Wattage | 20 | Electrical | page text | p17 |
| Electrical - Emergency Lighting | 20 | Electrical | page text | p17 |
| Electrical - Exterior Lighting | 15 | Electrical | page text | p17 |
| Interior Construction - Gypsum Board | 45 | Interior construction | page text | p17 |
| Interior Construction - Steel Panelling | 50 | Interior construction | page text | p17 |
| Furnishing - Cabinets | 25 | — | page text | p17 |
| Interior Construction - Wood Panelling | 30 | Interior construction | page text | p18 |
| Interior Construction - Poly Panelling | 50 | Interior construction | page text | p18 |
| Interior Construction - Doors | 30 | Interior construction | page text | p18 |
| Interior Construction - Partitions | 20 | Interior construction | page text | p18 |
| Flooring - Carpet | 15–25 | Interior finishes | page text | p18 |
| Flooring - Vinyl | 20 | Interior finishes | page text | p18 |
| Flooring - Concrete | 20 | Interior finishes | page text | p18 |
| Flooring - Tile | 15–30 | Interior finishes | page text | p18 |
| Flooring - Hardwood | 20–50 | Interior finishes | page text | p18 |
| Land Improvements - Parking Lot - Asphalt | 30 | Parking lots | page text | p16 |
| Land Improvements - Parking Lot - Gravel | 30 | Parking lots | page text | p16 |
| Wet Well | 50 | Sanitary sewer | page text | p18 |
| Dry Well | 50 | Sanitary sewer | page text | p18 |
| Valve Chamber | 50 | Water supply | page text | p18 |
| Holding Tank | 50 | — | page text | p18 |
| Linear - Bridges - Wearing Surface | 30 | Roadways | page text | p19 |
| Linear - Bridges - Substructure | 50–75 | Roadways | page text | p19 |
| Linear - Bridges - Superstructure | 25–75 | Roadways | page text | p19 |
| Linear - Culverts - Concrete | 75 | Storm sewer | page text | p19 |
| Linear - Culverts - Corrugated Steel | 25–40 | Storm sewer | page text | p19 |
| Linear - Culverts - HDPE / PVC | 50–80 | Storm sewer | page text | p19 |
| Linear - Stormwater Facility | 40 | Storm sewer | page text | p19 |
| Linear - Sidewalk - Concrete | 50 | Sidewalks and walkways | page text | p19 |
| Linear - Sidewalk - Paving Stone | 20 | Sidewalks and walkways | page text | p19 |
| Linear - Road Base - Asphalt - Curb | 80 | Roadways | page text | p19 |
| Linear - Road Base - Asphalt - Ditch | 50 | Storm sewer | page text | p19 |
| Linear - Road Base - Surface Treatment | 50 | Roadways | page text | p19 |
| Linear - Road Base - Gravel | 50 | Roadways | page text | p19 |
| Linear - Pipe - PVC | 50–80 | — | page text | p19 |
| Linear - Pipe - Concrete | 50–75 | — | page text | p19 |
| Linear - Pipe - HDPE | 50–80 | — | page text | p19 |
| Linear - Pipe - PE | 50–80 | — | page text | p19 |
| Linear - Pipe - DI | 50 | — | page text | p19 |
| Linear - Pipe - Copper | 50 | — | page text | p19 |
| Linear - Valves - Pressure Release | 50 | Water supply | page text | p19 |
| Linear - Valves - Globe | 50 | Water supply | page text | p19 |
| Linear - Valves - Gate | 25 | Water supply | page text | p19 |
| Linear - Valves - Air Release | 25 | Water supply | page text | p19 |
| Linear - Valves - Power Actuated | 20–30 | Water supply | page text | p19 |
| Linear - Valves - Valve Chamber | 50–80 | Water supply | page text | p19 |
| Linear - Valves - Maintenance Hatch | 50–80 | Water supply | page text | p19 |
| Linear - Fire Hydrant | 50–60 | Water supply | page text | p19 |
| Linear - Road Surface - Asphalt - Curb | 30 | Roadways | page text | p20 |
| Linear - Road Surface - Asphalt - Ditch | 25 | Storm sewer | page text | p20 |
| Linear - Road Surface - Surface Treatment | 3–7 | Roadways | page text | p20 |
| Linear - Streetlight Luminaires | 30 | Site lighting | page text | p20 |
| Linear - Streetlight Poles | 50 | Site lighting | page text | p20 |
| Linear - Traffic Signals | 25 | Traffic signals and other site electrical | page text | p20 |
Municipality of Meaford Asset Management Plan - Core Assets (Appendix 1 to Report CAO2022-28)
| As written | Years | System | Checked against | Page |
|---|---|---|---|---|
| Rural/Semi-Urban - Asphalt Surface | 25 | Roadways | page text | p39 |
| Rural/Semi-Urban - Asphalt Base | 50 | Roadways | page text | p40 |
| Rural - LCB Surface | 7 | Roadways | page text | p40 |
| Rural - LCB Base | 50 | Roadways | page text | p40 |
| Urban – Asphalt Surface | 30 | Roadways | page text | p40 |
| Urban – Asphalt Base | 80 | Roadways | page text | p40 |
| Culverts - Concrete | 75 | Storm sewer | page text | p79 |
| Culverts - Steel <3m | 60 | Storm sewer | page text | p79 |
| Bridge | 75 | Roadways | page text | p79 |
| Stormwater Collection Main | 80 | Storm sewer | page text | p111 |
| Local Main | 80 | Water supply | page text | p135 |
| Transmission Main | 80 | Water supply | page text | p135 |
| Storage (Water Tower) | 75 | Water supply | page text | p135 |
| Water Booster Pumping Station | 75 | Water supply | page text | p135 |
| Water Treatment Plant | 75 | Water supply | page text | p135 |
| Force main | 80 | Sanitary sewer | page text | p165 |
| Local Sewer | 80 | Sanitary sewer | page text | p165 |
| Trunk Sewer | 80 | Sanitary sewer | page text | p165 |
| Sanitary Pumping Station | 75 | Sanitary sewer | page text | p166 |
| Wastewater Treatment Plant | 75 | Sanitary sewer | page text | p166 |