unfinished.one

Ontario · Single-tier municipality · population 46,560 (2021)

Quinte West

Municipal website

Documents

Stated lives

48 rows, each as written in the document and linked to its page. Policies give accounting lives (amortization periods); plans give planning lives. Neither is a measured replacement age.

A09-POLICY-0034 Tangible Capital Asset Policy

As writtenYearsSystemChecked againstPage
Single Asset Buildings30—page textp38
Compound Buildings - Substructure95–110Foundationspage textp38
Compound Buildings - Shell - Roof15–35Roofingpage textp38
Compound Buildings - Shell - Other55–85Exterior enclosurepage textp38
Compound Buildings - Interior35–85Interior constructionpage textp38
Compound Buildings - HVAC25HVACpage textp38
Compound Buildings - Services - Other25—page textp38
Compound Buildings - Special Construction25—page textp38
Compound Buildings - Process Equipment30—page textp38
Compound Buildings - Electrical40Electricalpage textp38
Compound Buildings - Instrumentation20—page textp38
Compound Buildings - Piping50Plumbingpage textp38
Compound Buildings - Building and Process Structure60Superstructurepage textp38
Compound Buildings - Architectural20—page textp38
Compound Buildings - Services20—page textp38
Roads - Base35Roadwayspage textp36
Roads - Asphalt Surface (HDB;LCB)20Roadwayspage textp36
Roads - Surface Treatment (ST;G/S)20Roadwayspage textp36
Roads - Sidewalks35Sidewalks and walkwayspage textp36
Roads - Curbs and Gutters35Roadwayspage textp36
Bridges - Deck (Wood, Concrete)50–75Roadwayspage textp36
Bridges - Structure (Steel, Wood)50–75Roadwayspage textp36
Bridges - Wearing (Asphalt, Wood)15–20Roadwayspage textp37
Culverts50Storm sewerpage textp37
Street Lights (Arm, Hardware)45Site lightingpage textp37
Poles45—page textp37
Fixtures45—page textp37
Traffic Signals40Traffic signals and other site electricalpage textp37
Water Mains - Cast Iron50Water supplypage textp37
Water Mains - Polyethylene80Water supplypage textp37
Water Mains - CPP (Concrete Pressure Pipe)80Water supplypage textp37
Water Mains - Galv50Water supplypage textp37
Water Mains - Copper80Water supplypage textp37
Water Mains - AC80Water supplypage textp37
Water Mains - PVC80Water supplypage textp37
Hydrants60Water supplypage textp37
Sanitary Sewer Mains - Polyethylene80Sanitary sewerpage textp37
Sanitary Sewer Mains - Concrete80Sanitary sewerpage textp37
Sanitary Sewer Mains - Reinforced Concrete (RC)80Sanitary sewerpage textp37
Sanitary Sewer Mains - AC80Sanitary sewerpage textp37
Sanitary Sewer Mains - Clay Tile80Sanitary sewerpage textp37
Sanitary Sewer Mains - Vitrified Clay (VC)80Sanitary sewerpage textp38
Sanitary Sewer Mains - PVC80Sanitary sewerpage textp38
Storm Water Ponds60Storm sewerpage textp38

Water and Wastewater Asset Management Plan

As writtenYearsSystemChecked againstPage
Pipe Relining50Water supplypage textp22
Pipe Replacement100Water supplypage textp22
Pipe Relining50Sanitary sewerpage textp22
Pipe Replacement100Sanitary sewerpage textp22