46 rows, each as written in the document and linked to its page. Policies give accounting lives (amortization periods); plans give planning lives. Neither is a measured replacement age.

London Public Library Tangible Capital Assets Policy

As writtenYearsSystemChecked againstPage
Building Structures60—page textp2
Building Components - Shell (siding, windows, roofing)20Exterior enclosure, Roofingpage textp2
Building Components - Interiors (partitions, doors)30Exterior enclosure, Interior constructionpage textp2
Building Components - Services (HVAC, lighting, communication, plumbing etc.)20Plumbing, HVAC, Electricalpage textp2
Building Components - Site works (parking lots etc.)20Parking lotspage textp2

2023 Corporate Asset Management Plan

As writtenYearsSystemChecked againstPage
Distribution Mains80Water supplypage textp70
Transmission Mains90Water supplypage textp70
Service Connections60Water supplypage textp70
Valves50Water supplypage textp70
Hydrants50Water supplypage textp70
Chambers (main diameter <= 450mm )60Water supplypage textp70
Chambers (main diameter > 450mm)60Water supplypage textp70
Pressure Release Valve60Water supplypage textp70
Pump Stations (Including Rechlorination)35Water supplypage textp70
Storage Reservoirs96Water supplypage textp70
Local sewers (<450 mm)95Sanitary sewerpage textp95
Trunk sewers (450 mm to <1500 mm)100Sanitary sewerpage textp95
Trunk sewers (> and equal to 1500 mm)100Sanitary sewerpage textp95
Storage tanks100Sanitary sewerpage textp95
Pump stations44Sanitary sewerpage textp95
Forcemains100Sanitary sewerpage textp95
Storm sewers <450mm diameter100Storm sewerpage textp127
Storm sewers 450mm>= to <1,500mm diameter100Storm sewerpage textp127
Storm sewers >=1,500 mm diameter100Storm sewerpage textp127
Open Conveyance100Storm sewerpage textp127
Storm Water Management Facilities100Storm sewerpage textp127
SWM Green Infrastructure25Storm sewerpage textp127
Minor Treatment80Storm sewerpage textp127
Minor Culverts (Up to 1.8m in diameter)60Storm sewerpage textp127
Expressway25Roadwayspage textp157
Rural Throughfare45Roadwayspage textp157
Rural Connector45Roadwayspage textp157
Civic Boulevard45Roadwayspage textp157
Urban Throughfare45Roadwayspage textp157
Main Street45Roadwayspage textp157
Neighbourhood Street45Roadwayspage textp157
Neighbourhood Connector45Roadwayspage textp157
Rapid Transit Boulevard45Roadwayspage textp157
Interchange Ramps45Roadwayspage textp157
Bridges80Roadwayspage textp158
Footbridges80Roadwayspage textp158
Minor Culverts (between 1.8m to 3m span)50Storm sewerpage textp158
Major Culverts (greater than and equal to 3m span)50Storm sewerpage textp158
Street Lights30Site lightingpage textp159
Signals20Traffic signals and other site electricalpage textp159
Surface Lots45Roadwayspage textp197