Ontario · Single-tier municipality · population 14,967 (2021)
Kenora
Documents
AF-6-1 Tangible Capital Asset Policy (By-law 34-2026) · 2026
Capital asset policy
City of Kenora Asset Management Plan 2025 · 2025
Asset management plan · No useful-life table. Lives appear only as replacement-cost-weighted average EUL per segment in bar charts ("Estimated Useful Life vs. Asset Age" / "Average Age vs Average EUL" figures, one per asset category); category axis labels are not extractable as text from most charts, so values were not transcribed.
Stated lives
38 rows, each as written in the document and linked to its page. Policies give accounting lives (amortization periods); plans give planning lives. Neither is a measured replacement age.
AF-6-1 Tangible Capital Asset Policy (By-law 34-2026)
| As written | Years | System | Checked against | Page |
|---|---|---|---|---|
| Buildings - Structure | 75 | Superstructure | page text | p15 |
| Buildings - Exterior Components | 50 | Exterior enclosure | page text | p15 |
| Buildings - Interior Components | 25 | Interior construction | page text | p15 |
| Buildings - Mechanical System | 20 | HVAC | page text | p15 |
| Buildings - Electrical System | 20 | Electrical | page text | p15 |
| Buildings - Security System | 20 | — | page text | p15 |
| Buildings - Elevator | 20 | Conveying | page text | p15 |
| Buildings - Site Services | 50 | — | page text | p15 |
| Road Network - Paved | 25 | Roadways | page text | p16 |
| Road Network - Surface Treated | 15 | Roadways | page text | p16 |
| Road Network - Gravel | 10 | Roadways | page text | p16 |
| Bridges - Superstructure | 50 | Roadways | page text | p16 |
| Bridges - Substructure | 15 | Roadways | page text | p16 |
| Sidewalks - Concrete | 50 | Sidewalks and walkways | page text | p16 |
| Sidewalks - Brick | 40 | Sidewalks and walkways | page text | p16 |
| Storm Sewers - Pipe - Conc/PE/PVC | 50 | Storm sewer | page text | p16 |
| Storm Sewers - Pipe - STL | 25 | Storm sewer | page text | p16 |
| Storm Sewers - Culvert - PE/PVC | 50 | Storm sewer | page text | p16 |
| Storm Sewers - Culvert - STL | 20 | Storm sewer | page text | p16 |
| Storm Sewers - Manholes | 50 | Storm sewer | page text | p16 |
| Storm Sewers - Catch Basins | 50 | Storm sewer | page text | p16 |
| Miscellaneous - Traffic Signals | 20 | Traffic signals and other site electrical | page text | p16 |
| Miscellaneous - Streetlights | 20 | Site lighting | page text | p16 |
| Water Mains - Ductile Iron | 60 | Water supply | page text | p17 |
| Water Mains - Cast Iron | 50 | Water supply | page text | p17 |
| Water Mains - PVC | 75 | Water supply | page text | p17 |
| Water Mains - PE | 75 | Water supply | page text | p17 |
| Water Mains - Valves | 75 | Water supply | page text | p17 |
| Water Mains - Hydrants | 75 | Water supply | page text | p17 |
| Booster Stations | 75 | Water supply | page text | p17 |
| Tanks | 75 | — | page text | p17 |
| Wastewater Mains - Concrete | 100 | Sanitary sewer | page text | p18 |
| Wastewater Mains - PVC | 75 | Sanitary sewer | page text | p18 |
| Wastewater Mains - Metal | 25 | Sanitary sewer | page text | p18 |
| Wastewater Mains - Clay Tile | 50 | Sanitary sewer | page text | p18 |
| Wastewater Mains - PE | 100 | Sanitary sewer | page text | p18 |
| Wastewater Mains - Manholes | 50 | Sanitary sewer | page text | p18 |
| Pumping / Lift Stations | 75 | Sanitary sewer | page text | p18 |